MCP Waters-The Science of What's Possible
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     



This Article
Right arrow Full Text (PDF)
Right arrow Supplemental Data
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Glossary
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Szájli, E.
Right arrow Articles by Medzihradszky, K. F.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Szájli, E.
Right arrow Articles by Medzihradszky, K. F.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Submitted on March 13, 2008
Revised on July 7, 2008
Accepted on July 24, 2008

Investigating the quantitative nature of MALDI-TOF MS

Emília Szájli, Tamás Fehér, and Katalin F. Medzihradszky

Proteomics Research Group, Biological Research Center, Hungarian Academy of Sciences, Szeged H-6726

Corresponding Author: folkl{at}cgl.ucsf.edu

Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) has been applied by several groups to relative quantitative measurements. At the same time, the non-quantitative character of this method has been widely reported. We conducted experiments to test the reliability of this technique for quantitation, using the statistical method of inverse confidence limit calculation for the first time in this context. The relationship between relative intensities of known amounts of standard peptides and their concentration ratios was investigated. We found that the concentration ratios determined by relative intensity measurements were highly inaccurate, and strongly influenced by the molecular milieu of the sample analyzed. Thus, we emphasize the necessity of using the sample itself for calibration. We also performed experiments using an isotope-labeled derivative of the analyte as an internal standard for calibration line generation. As expected, the use of such standard led to a dramatic increase in precision and a less pronounced improvement in accuracy. We recommend performing a similar statistical analysis as a demonstration of reliability for every system where MALDI-TOF MS is used for quantitative measurements.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 All ASBMB Journals   Journal of Biological Chemistry 
 Journal of Lipid Research   ASBMB Today 
Copyright © 2008 by the American Society for Biochemistry and Molecular Biology.